Statistically coherent calibration of X-Ray Fluorescence Spectrometry for major elements in rocks in minerals.

Verma, Surendra P. y Verma, Sanjeet K. y Rivera Gómez, María Abdelaly y Torres Sánchez, Darío y Díaz González, Lorena y Amezcua Valdez, Alejandra y Rivera Escoto, Beatriz Adriana y Rosales Rivera, M. y Armstrong Altrin, John S. y López Loera, Héctor y Velasco Tapia, Fernando y Pandarinath, Kailasa (2018) Statistically coherent calibration of X-Ray Fluorescence Spectrometry for major elements in rocks in minerals. Journal of spectroscopy, 2018. pp. 1-13. ISSN 2314-4939

[img]
Vista previa
Texto
N41_Vermaetal_2018_JS.pdf - Versión Publicada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

Download (1MB) | Vista previa

Resumen

We applied both the ordinary linear regression (OLR) and the new uncertainty weighted linear regression (UWLR) models for the calibration and comparison of a XRF machine through 59 geochemical reference materials (GRMs) and a procedure blank sample. )e mean concentration and uncertainty data for the GRMs used for the calibrations (Supplementary Materials) (available here) filewere achieved from an up-to-date compilation of chemical data and their processing from well-known discordancy and significance tests. )e drift-corrected XRF intensity and its uncertainty were determined from mostly duplicate pressed powder pellets. )e comparison of the OLR (linear correlation coefficient r∼0.9523–0.9964 and 0.9771–0.9999, respectively, for before and after matrix correction) and UWLR models (r∼0.9772–0.9976 and 0.9970–0.9999, respectively) clearly showed that the latter with generally higher values of r is preferable for routine calibrations of analytical procedures. Both calibrations were successfully applied to rock matrices, and the results were generally consistent with those obtained in other laboratories although the UWLR model showed mostly narrower confidence limits of the mean (slope and intercept) or lower uncertainties than the OLR. Similar sensitivity (∼2.69–46.17 kc·s1·%1 for the OLR and ∼2.78–59.69 kc·s1·%1 for the UWLR) also indicated that the UWLR could advantageously replace the OLR model. Another novel aspect is that the total uncertainty can be reported for individual chemical data. If the analytical instruments were routinely calibrated from the UWLR model, this action would make the science of geochemistry more quantitative than at present.

Tipo de elemento: Article
Materias: Q Ciencia > QD Química
Q Ciencia > QE Geología
Divisiones: Ciencias de la Tierra
Usuario depositante: Dr Fernando Velasco-Tapia
Creadores:
CreadorEmailORCID
Verma, Surendra P.NO ESPECIFICADONO ESPECIFICADO
Verma, Sanjeet K.NO ESPECIFICADONO ESPECIFICADO
Rivera Gómez, María AbdelalyNO ESPECIFICADONO ESPECIFICADO
Torres Sánchez, DaríoNO ESPECIFICADONO ESPECIFICADO
Díaz González, LorenaNO ESPECIFICADONO ESPECIFICADO
Amezcua Valdez, AlejandraNO ESPECIFICADONO ESPECIFICADO
Rivera Escoto, Beatriz AdrianaNO ESPECIFICADONO ESPECIFICADO
Rosales Rivera, M.NO ESPECIFICADONO ESPECIFICADO
Armstrong Altrin, John S.NO ESPECIFICADONO ESPECIFICADO
López Loera, HéctorNO ESPECIFICADONO ESPECIFICADO
Velasco Tapia, FernandoNO ESPECIFICADONO ESPECIFICADO
Pandarinath, KailasaNO ESPECIFICADONO ESPECIFICADO
Fecha del depósito: 07 Oct 2019 21:02
Última modificación: 18 Mayo 2023 18:58
URI: http://eprints.uanl.mx/id/eprint/16904

Actions (login required)

Ver elemento Ver elemento

Downloads

Downloads per month over past year