Diagnostic Accuracy of the Triglyceride and Glucose Index for Insulin Resistance: A Systematic Review
Sánchez García, Adriana y Rodríguez Gutiérrez, René y Mancillas Adame, Leonardo G. y González Nava, Victoria y Díaz González Colmenero, Alejandro y Solís, Ricardo Cesar y Alvarez Villalobos, Neri Alejandro y González González, José Gerardo (2020) Diagnostic Accuracy of the Triglyceride and Glucose Index for Insulin Resistance: A Systematic Review. International Journal of Endocrinology, 2020. pp. 1-7. ISSN 1687-8337
|
Texto
25583.pdf - Versión Publicada Available under License Creative Commons Attribution Non-commercial No Derivatives. Download (1MB) | Vista previa |
Resumen
Introduction. The triglyceride and glucose (TyG) index has been described as a biochemical marker of insulin resistance (IR); however, its diagnostic accuracy remains uncertain. Objective. To summarize the evidence assessing the diagnostic accuracy of the TyG index regarding IR. Methods. A comprehensive search in MEDLINE, EMBASE, Web of Science, and Scopus was performed without any language restriction. Studies assessing the diagnostic accuracy of the TyG index against the hyperinsulinemic-euglycemic clamp (HIEC) or any other IR biochemical were assessed independently and in duplicate. Diagnostic accuracy measures (sensitivity, specificity, positive predictive value, negative predictive value, and likelihood ratios) were extracted independently and in duplicate. The QUADAS-2 tool was used to assess the risk of bias of independent studies. Results. We identified 15 eligible studies with 69,922 participants and an overall quality of low to moderate. The TyG index was evaluated by HIEC and HOMA as reference tests. The highest achieved sensitivity was 96% using HIEC, and the highest specificity was of 99% using HOMA-IR, with a cutoff value of 4.68. AUC values varied from 0.59 to 0.88. Cutoff values for IR were variable between studies, limiting its comparability. Conclusion. In this systematic review, we found moderate-to-low quality evidence about the usefulness of the TyG index as a surrogate biochemical marker of IR. Due to the lack of a standardized IR definition and heterogeneity between studies, further validation and standardized cutoff values are needed to be used in clinical practice.
Tipo de elemento: | Article | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Materias: | R Medicina > RC Medicina Interna, Psiquiatría, Neurología | |||||||||||||||||||||||||||
Divisiones: | Medicina | |||||||||||||||||||||||||||
Usuario depositante: | Editor Repositorio | |||||||||||||||||||||||||||
Creadores: |
|
|||||||||||||||||||||||||||
Fecha del depósito: | 14 Jun 2023 22:40 | |||||||||||||||||||||||||||
Última modificación: | 14 Jun 2023 22:40 | |||||||||||||||||||||||||||
URI: | http://eprints.uanl.mx/id/eprint/25583 |
Actions (login required)
Ver elemento |